Generator / Transfer
Switch Operation GenTran Type
There are 3 basic operations. The process is the same, whether for test
purposes or for actual power failures.
1. Get the generator started without any electrical load.
- If necessary, move generator to proper
location for operation. (Remove any coverings.)
- Connect safety ground wire between ground
rod and generator.
- Check oil level. (Low oil level will
cause sensor to prevent generator from running.)
- For gasoline models, fill tank with
gasoline. Wipe off any spillage.
- Plug twist-lock extension cord into
generator and weatherproof outlet box. They only need a small
turn (clockwise to lock.)
- Pull choke lever for initial start-up.
- For electric start units, turn key or push
button to start.
- Otherwise, pull cord to start engine.
- Once motor is started, push choke lever
back in to normal position.
- Allow motor to run for 5 minutes or so to
warm up.
- At transfer switch, you can verify that
power from generator is functioning by plugging a light into the outlet
on the transfer switch.
2. Switch circuits over from the utility feed to the generator feed.
On the transfer switch panel:
- Flip individual circuit switches from
Utility position to Generator position. Depending on load, you
can switch as many or as few switches as desired.
- Monitor the 2 load meters on the panel to
see how much power is being used. Each meter should not exceed
½ the rated (running or constant) rating of the generator.
The 2 meters do not usually register identical amounts.
- If the load meters show too much power
being used for the generator, or to prevent items from being powered,
shut
off individual circuit switches.
3. When finished with the test, or utility power is back on:
- On transfer switch panel, return all
switches to Utility position.
- Turn off generator.
- Unplug the twist-lock extension cord. .
- Disconnect ground wire at generator.
- Allow the generator to cool completely
before storing.